Adpol manufactures precision cut lengths of solid rubber extrusions, cord and tubing for industrial, aerospace and specialist applications. Length is defined as the finished end-to-end dimension of the relaxed cut piece.
Unless otherwise specified, Adpol class L2 shall apply, subject to profile capability. Agreed drawing tolerances take precedence.
Technical reference: Adpol_CL01 | Revision ACut Length Tolerances
All values are in millimetres except the percentage row. Each range excludes its lower limit and includes its upper limit.
| Nominal cut length (mm) | L1 Precision | L2 Good quality | L3 Non-critical |
|---|---|---|---|
| 0–40 | ±0.70 | ±1.00 | ±1.60 |
| >40–63 | ±0.80 | ±1.30 | ±2.00 |
| >63–100 | ±1.00 | ±1.60 | ±2.50 |
| >100–160 | ±1.30 | ±2.00 | ±3.20 |
| >160–250 | ±1.60 | ±2.50 | ±4.00 |
| >250–400 | ±2.00 | ±3.20 | ±5.00 |
| >400–630 | ±2.50 | ±4.00 | ±6.30 |
| >630–1000 | ±3.20 | ±5.00 | ±10.00 |
| >1000–1600 | ±4.00 | ±6.30 | ±12.50 |
| >1600–2500 | ±5.00 | ±10.00 | ±16.00 |
| >2500–4000 | ±6.30 | ±12.50 | ±20.00 |
| >4000 | ±0.16% | ±0.32% | ±0.50% |
Above 4000 mm, calculate the tolerance from the nominal length. Example: 5000 mm at L2 = ±16.00 mm, giving acceptable limits of 4984.00–5016.00 mm.
Tolerance Class Selection
L2 – Good quality: Adpol’s normal tolerance class.
L1 – Precision: Tighter tolerances, subject to confirmation of material and cutting process capability.
L3 – Non-critical: May be agreed for non-critical lengths or profiles that are difficult to handle without stretching.
Thin, Soft and Stretchy Profiles
Thin, soft or highly extensible rubber profiles may stretch under very light handling loads. Feeding, pulling, lifting and straightening can affect the length during cutting and measurement. The material may shorten again when released and allowed to recover.
These profiles may require L3 or a wider, product-specific tolerance. Achievable tolerances depend on material, profile geometry, cut length and cutting method. Representative samples or trials may be required to confirm capability.
Any wider tolerance must be agreed in writing before manufacture and is not an automatic additional allowance.
Measurement and Inspection
Measure finished pieces in a relaxed and stabilised condition, without tensile load. Support the full length on a flat surface and align gently without stretching. Avoid allowing long pieces to hang over an edge.
Use suitable calibrated equipment and a consistent end reference, avoiding deformation of the ends. For critical components, agree recovery time, conditioning, support and measurement methods before production.
Lengths required under a defined load or in an installed condition must have separately specified acceptance limits.
Separate Tolerance Requirements
Cross-sectional dimensions are covered separately by Adpol_Ext01 – Rubber Extrusion Tolerances. Thin cut sections may require the ISO 3302-1 EC tolerance categories rather than the L table.
Sponge and cellular products, joined gaskets, cut angles and end squareness require separately agreed requirements where relevant.
Drawing and Quotation Reference
Unless otherwise specified, cut lengths to Adpol_CL01 Class L2. Wider tolerances for thin, soft or highly extensible profiles shall be agreed in writing before manufacture.
Adpol Technical Standard
Document: Adpol_CL01
Revision: A
Status: Company Standard
Default class: L2
Reference: ISO 3302-1:2014. This guide does not reproduce the full standard.
Specific Tolerance Requirements?
Our technical team can advise on achievable manufacturing tolerances based on your component design, material selection and intended application.
Please discuss critical dimensions and special tolerance requirements with Adpol prior to placing an order.
AS9100 Rev D | ISO 9001 | Made in Britain