Rubber Moulding and Flash Tolerances

Adpol manufactures solid rubber moulded components for industrial, aerospace and specialist applications. The following tolerances apply to moulded dimensions and flash height.

Adpol Standard Tolerances: M2 / X2

Unless otherwise specified, Adpol classes M2 and X2 shall apply. Agreed drawing or contractual tolerances take precedence.

Technical reference: Adpol_M01 | Revision A

Moulding Dimensional Tolerances

All values are in millimetres except the percentage row. Each range excludes its lower limit and includes its upper limit.

Nominal dimension (mm)M1M2M3M4
FixedClosedFixedClosedFixedClosedFixedClosed
0–4±0.08±0.10±0.10±0.15±0.25±0.40±0.50±0.50
>4–6.3±0.10±0.12±0.15±0.20±0.25±0.40±0.50±0.50
>6.3–10±0.10±0.15±0.20±0.20±0.30±0.50±0.70±0.70
>10–16±0.15±0.20±0.20±0.25±0.40±0.60±0.80±0.80
>16–25±0.20±0.20±0.25±0.35±0.50±0.80±1.00±1.00
>25–40±0.20±0.25±0.35±0.40±0.60±1.00±1.30±1.30
>40–63±0.25±0.35±0.40±0.50±0.80±1.30±1.60±1.60
>63–100±0.35±0.40±0.50±0.70±1.00±1.60±2.00±2.00
>100–160±0.40±0.50±0.70±0.80±1.30±2.00±2.50±2.50
>160±0.30%±0.40%±0.50%±0.70%±0.80%±1.30%±1.50%±1.50%

Fixed and Closure Dimensions

Fixed (F): Dimensions unaffected by mould-part displacement or closure variation.

Closure (C): Dimensions influenced by mould closure, flash or displacement between mould parts.

Fixed dimensions use their own nominal size; closure tolerances use the largest closure dimension.

F – FixedCClosureUpper mouldLower mouldRubber partIllustrative mould cross-section

Flash Tolerances

Flash height is classified independently of dimensional tolerances. Specify flash extension separately where functionally critical.

ClassMaximum flash height (mm)Description
X10.10Precision
X20.50Accurate
X31.00Normal
X42.00Rough

X0 (no flash) applies only away from parting lines; X5 has no limit. Adpol default flash class: X2.

Material and Manufacturing Considerations

M1 requires capability confirmation; M3 or M4 may be agreed for non-critical features. Compound shrinkage and tooling design affect achievable tolerances. Confirm critical features before tooling release. Precision sealing rings, cellular mouldings and special products require separately agreed specifications.

Measurement and Inspection

Measure relaxed, stabilised parts using calibrated equipment without distortion. Agree measurement method and conditioning for critical dimensions.

Adpol Technical Standard

Document: Adpol_M01

Revision: A

Status: Company Standard

Default classes: M2 / X2

Reference: ISO 3302-1:2014.

Specific Tolerance Requirements?

Our technical team can advise on achievable manufacturing tolerances based on your component design, material selection and intended application.

Please discuss critical dimensions and special tolerance requirements with Adpol prior to placing an order.

AS9100 Rev D | ISO 9001 | Made in Britain