Rubber Extrusion Tolerances

Adpol manufactures precision solid rubber extrusions, including silicone profiles, cord and tubing. The following cross-sectional dimensional tolerances apply to unsupported solid rubber extrusions, with reference to ISO 3302-1:2014.

Adpol Standard Tolerance: Class E2

Unless otherwise specified, Adpol class E2 shall apply. Agreed drawing tolerances or alternative classes agreed in writing take precedence.

Technical reference: Adpol_Ext01 | Revision A

Cross-sectional Dimensional Tolerances

All values are in millimetres except the percentage row. Each range excludes its lower limit and includes its upper limit.

Nominal dimension (mm)E1
High quality
E2
Good quality
E3
Non-critical
0–1.5±0.15±0.25±0.40
>1.5–2.5±0.20±0.35±0.50
>2.5–4±0.25±0.40±0.70
>4–6.3±0.35±0.50±0.80
>6.3–10±0.40±0.70±1.00
>10–16±0.50±0.80±1.30
>16–25±0.70±1.00±1.60
>25–40±0.80±1.30±2.00
>40–63±1.00±1.60±2.50
>63–100±1.30±2.00±3.20
>100±1.30%±2.00%±3.20%

Above 100 mm, calculate the tolerance as a percentage of the nominal dimension. Example: 120 mm at E2 = ±2.40 mm; acceptable limits are 117.60–122.40 mm.

Tolerance Class Selection

E2 – Good quality: Adpol’s default tolerance class.

E1 – High quality: Tighter tolerances, subject to confirmation of compound, geometry and process capability.

E3 – Non-critical: May be agreed where wider variation is acceptable.

Profile Design and Material Considerations

Profile complexity, thin walls, soft compounds and differential shrinkage can affect dimensional capability. Agree requirements for lips, slots, hollow sections and other flexible features before tooling or production.

For tubing, inside diameter, outside diameter and wall thickness are geometrically linked. Agree which dimensions control acceptance and avoid incompatible limits.

Measurement and Inspection

Measure extrusions in a relaxed, unstretched and stabilised condition using suitable calibrated instruments. Avoid contact pressure that compresses soft walls or closes hollow sections. For critical features, agree measurement methods, conditioning, sample locations and acceptance criteria. Optical measurement or checking fixtures may be preferable to callipers.

Select the tolerance row using the nominal dimension, not the measured result.

Separate Tolerance Requirements

Cut lengths are covered separately by Adpol_CL01 – Rubber Cut Length Tolerances ».

Sponge and cellular profiles require separately agreed tolerances. Mandrel-supported and surface-ground products require their applicable tolerance categories. Straightness, twist, angles, surface finish, flash, cut squareness, splices and fabricated gasket dimensions should be specified separately where function requires.

Drawing and Quotation Reference

Unless otherwise specified, solid rubber extrusion cross-sectional dimensions to Adpol_Ext01 Class E2. Cut-length tolerances to be specified separately.

Adpol Technical Standard

Document: Adpol_Ext01

Revision: A

Status: Company Standard

Default class: E2

Reference: ISO 3302-1:2014. This guide does not reproduce the full standard.

Specific Tolerance Requirements?

Our technical team can advise on achievable manufacturing tolerances based on your component design, material selection and intended application.

Please discuss critical dimensions and special tolerance requirements with Adpol prior to placing an order.

AS9100 Rev D | ISO 9001 | Made in Britain